NEW - Ultra High Efficiency
High Density Power Distribution - Data Centers
Distributing power efficiently in today's high-density data centers have become a challenge. Power is a basic critical requirement for virtually all systems. NAAT can help you evaluate your requirements and design and supply the appropriate cooling system for your application. NAAT is an authorized partner of virtually all major vendors of power systems.
Introducing the New APC In-Row 288 KVA High Density
ULTRA HIGH EFFICIENCY Power Distribution System >
400/240V Technology - Uses only 1/5 the space of traditional systems.
Yes - 400/240V power can safely and be legally deployed now in data centers here in US-North America!
Imagine over 530 KW of Power Distribution in one standard Rack Space!
(or 265 KW with fully 2N Redundancy)
N = Single System - No redundancy
2N = 2 fully independent systems each equal to power load - 100% redundancy
Here in the US our power systems are normally based on 208/120V power distribution to IT equipment. So why and how can we use 400/240 V power in our racks ?
In the US we use traditional 208/120V power distribution. By transforming our standard US 480V power to "Euro" 400/240v power at the PDU we can feed 240V to virtually any modern IT equipment, since they all have universal power supplies that can operate at 100-250V. Moreover, most new server power supplies operate more efficiently at 240 Volts! (up to 20 % more efficiently).
What are the advantages of 400/240 V power?
Ultra High Efficiency !! More Power - Less Heat
Delivers twice the power over the same conductor size, minimizing cable cost and losses.
Smaller Size - only 12" wide yet supports up to 288 KVA!
It is a totally Modular
System.

The system features:
> Fully enclosed, Hot Swappable circuit breaker modules with monitoring
> Pre-Terminated, plug-in Power Whips
> Plug-in rack PDUs
> "Plug & Power", touch safe fully enclosed design, allows rapid moves, adds and changes of power to racks - all of which can be accomplished safely while the unit is energized - without a power down !
This Power Distribution System features
Total and Individual Circuit Monitoring and Energy Management
You can monitor individual circuits Amps, Volts, KVA, KW, and even accumulated KWH.
You can program alarm and early warning set points for current to prevent circuit overloads (both locally and remotely).
Rack power modules,
whips (in single and 3 phase) provides up to
11.5 KW per each rack PDU
- all just plug-in & deploy as needed.
Ideal for Bladeservers
-
Supports
46 KW per rack
(23KW with 2N Redundancy)

The New Standard in High Density PDUs. It changes all the rules. This sets a
new Paradigm for high-density power distribution in Data Centers.
You have to see it to believe it. <click for data sheet
Best of all it is cost effective
Starting at under $20,000
With over 20 years of experience, NAAT will work with your IT and Faculties staff, as well as architects, construction contactors to design and deliver a cost-effective, flexible site that will grow with your organization's ever changing IT environment.
Please contact NAAT's Network Services team to discuss your Organization's requirements.
800-392-3299 www.naat.com info@naat.com